TC100N FIXED GAS DETECTOR

Description:

TC100N fixed gas detector adopts advanced catalytic gas sensor or electrochemical sensor, which can translate the gas concentration in the air to the digital signal output.

Applications:

The detector working with gas controller can be used to detect gas in refinery, chemical plant, LPG station, boiler room, painting plant and other places with gas exists.

Features:

4-20mA or RS485 output optional
ATEX certificate

Technical Data:

      • Sensor Type: Catalytic or electrochemical gas sensor.
      • Sampling Method: Natural diffusion
      • Accuracy: ≤±5%FS
      • Response Time (T90): ≤30s (LEL) / ≤60s (toxic gas)
      • Working Condition:
      • Temperature: -40~70℃ (LEL) / -20~50℃ (toxic gas)
      • Humidity: ≤95%RH (no condensation)
      • Explosion-proof grade: ExdⅡCT6
      • Protection Grade: IP65
      • Working Voltage: DC24V±25%
      • Working Pressure: 86kPa~106kPa
      • Signal Output: 4-20mA 3-line
      • Consumption: 2W
      • Cable Required:
      • ≥1.5mm2 x 3 core cable (4-20mA type)
      • ≥1.5mm2 x 4 core cable (RS485 type)
      • Transmission Distance: ≤1000m
      • Dimension: l×b×h mm 196×186×68.5
      • Weight: about 1200g

Package and Accessories:

      • pc per carton, size: 25*27*13cm